Your position: Home > Products > Customized Service

GDJ-M High pressure hydraulic diaphragm dosing metering pump

Type:
GDJ1-M-2/5
Flow L/h:
2
Max Pressure MPa:
5
Inlet pipe connections(D):
Φ12 (outside diameter) *3 hose
Outlet pipe connections(C):
Φ12 (outside diameter) *3 hose
We're here to help:
Easy ways to get the answers you need.
download: Catalogue
Description
Application
Features
Technical data
■ Description
GDJ-M High pressure hydraulic diaphragm dosing metering pump is widely utilized across various industries including petroleum, chemical industry, spinning, food industry, papermaking, atomic energy, power plants, plastics, pharmacy, water works, environmental protection, and more.

hydraulic diaphragm metering pump for sale

1. It is equipped with an installed stroke adjustor and can be remotely controlled.
2. It is leakage-free, offers low noise, and is easy to operate and maintain.
3. It provides more precise measurement compared to mechanical diaphragm pumps and better sealing compared to plunger pumps.
4. It incorporates an advanced overload protection, limiting displacement, and a three-valve structure for adding oil. This not only ensures sufficient hydraulic oil in the hydraulic chamber but also prevents excess oil and hydraulic shock. This helps to achieve balance on both sides of the diaphragm and extends its service life.
5. The diaphragms are multi-layered. The first layer is made of super tough acid-resistant Teflon, the second layer is EPDM, the third layer is a 3.0mm SS304 support iron core, the fourth layer is reinforced nylon fiber, and the outermost layer is coated with EPDM gum elastic.

industrial electric chemical metering pump

hydraulic diaphragm metering pump for hydrochloric acid, sulfuric acid

Major performance parameters of GDJ-M Hydraulic diaphragm dosing metering pump:
1. Single-joint maximum flow: 40000 L/h.
2. Maximum discharge pressure: 50 MPa.
3. Steady state accuracy: ±1%.
4. Media Viscosity: 0-800mm²/s.
5. Temperature of transporting media can reach over 450℃.

high-performance diaphragm pump

chemical diaphragm dosing pump

GDJ-M High pressure hydraulic diaphragm dosing metering pump accessories:

alloy hydraulic diaphragm chemical dosing pump accessories

chemical dosing pump diaphragm for water treatment plant accessories

Chinese factory chemical dosing pump diaphragm

high-performance diaphragm pump accessories

hydraulic diaphragm dosing metering pump chrome worm

hydraulic diaphragm dosing pump accessories

Hydraulical Diaphragm

industrial electric high pressure metering plunger hydraulic pump accessories

Inlet of high pressure hydraulic diaphragm dosing pump

Inlet of hydraulic diaphragm dosing metering pump

large flow hydraulic diaphragm metering pump with high pressure accessories

metering dosing pump diaphragm for water treatment plant accessories

Outlet of hydraulic diaphragm dosing pump

PTFE Pump Head of high pressure hydraulic dosing metering pump

■ Application
GDJ-M High pressure hydraulic diaphragm dosing pump is suitable for handling various liquids, including clear water at normal temperature, highly corrosive, volatile, flammable, explosive, highly toxic, foul-smelling, highly corrosive, high-density, medium-viscosity, radioactive, or other precious liquids. It can also transport suspended liquids. To prevent accidents caused by the mixing of the medium and hydraulic oil after the diaphragm ruptures, as well as for handling flammable, explosive, highly toxic, and valuable liquids, a double diaphragm metering pump equipped with a diaphragm rupture alarm device can be selected.

high pressure large flow hydraulic diaphragm plunger metering pump

large flow hydraulic diaphragm metering pump

GDJ-M Hydraulic diaphragm metering pump is suitable for various industries and applications, including petroleum, petrochemical and chemical processes that require high pressure and large flow rates, as well as land and offshore oil and gas skid-mounted systems for hazardous chemicals injection and delivery. It can also be used in nuclear power, military, and other special process applications, as well as in environmental protection, pharmaceutical, paper, food, and other key processes of the industry.

water treatment diaphragm chemical dosing pump

■ Features
Main features of GDJ-M High pressure hydraulic diaphragm dosing metering pump:
1. Each pump has with internal pressure relief valve protecting the pump from over-pressure conditions.
2. The flow rate can adjusted via a unique adjusting mechanism from 0-100%.
3. The adjustment can be carried out when the pump is in operation or at the stop.
4. The steady rate accuracy is ±1% from 30%-100% of the maximum output. High measurement accuracy.
5. Automatic operation is achieved by variable speed drive.
6. A double diaphragm with a diaphragm rupture detecting system is available to prevent accidents caused by a mixture of hydraulic oil and liquid after diaphragm ruptures.
7. Design and manufacturing standard GB/T7782-2008.
8. It can remove the gas remaining in the hydraulic oil and keep the hydraulic oil rigid.
9. Completely sealed and no leakage.
10. The control system of the diaphragm is in full rear position.

Details of GDJ-M High pressure hydraulic diaphragm dosing metering pump:

alloy hydraulic diaphragm chemical dosing pump details

custom-made mechanical diaphragm metering dosing pump details

high pressure hydraulic diaphragm plunger metering pump details

high pressure metering pump plunger dosing pump details

hydraulic diaphragm plunger metering pump details

industrial electric high pressure hydraulic diaphragm dosing metering pump details

industrial electric plunger metering pump chemical metering pump details

The first High-performance diaphragm pump:
1. Standard stainless steel liquid end: single head maximum flow rate 40,000 L/h, maximum pressure 50MPa.
2. Standard PVC liquid end: single head maximum flow rate 10,000 L/h, maximum pressure 10 bar.
3. Maximum flow rate of 10000 liters/hour in a single head, maximum pressure 10 bar.
4. Built-in combined safety valve to prevent excess pressure and automatic venting.
5. Measuring accuracy ± 1%.
6. Conveying medium temperature 100 ℃, special circumstances can reach 350 ℃.
7. Diaphragm PTFE, easy to install without leakage.
8. Using the latest technology, automatic control of oil replenishment, is safe and reliable.
9. Diaphragm pump (on-site/remote) rupture detection can choose pressure or electrolytic liquid type transmission end lubricant and hydraulic oil hydraulic end completely isolated low maintenance costs.

Hydraulic end:
1. A variety of standard hydraulic end forms including high-performance diaphragm pump heads, metal diaphragm pump head
2. Optional insulation jacket and other special hydraulic end forms
3. Diaphragm pumps can choose pressure or electrolyte type double diaphragm leakage detection (local/remote) alarm.
4. The pump head, check valve, diaphragm, plunger, packing, and other materials have special options.
5. High-precision inlet and outlet check valves with single ball valve, double ball valve, cone valve, and other optional configurations
■ Technical data
GDJ1-M high pressure hydraulic diaphragm dosing metering pump
Parameters

Type

Flow

L/h

Max Pressure MPa

inlet pipe connections(D)

outlet pipe connections(C)

Motor

0.12kW

Motor

0.18kW

GDJ1-M-2/5

2

 

5

Φ12 (outside diameter) *3 hose

Φ12 (outside diameter) *3 hose

GDJ1-M3.2/3.2

3.2

 

3.2

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ1-M-5/2.0

5

 

2.0

GDJ1-M-8/1.3

8

 

1.3

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ1-M-14/0.8

14

 

0.8

GDJ1-M-10/5

10

 

5

Φ12 (outside diameter) *3 hose

Φ12 (outside diameter) *3 hose

GDJ1-M-12.5/4

12.5

 

4

GDJ1-M-16/3.2

16

 

3.2

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ1-M-20/2.5

20

 

2.5

GDJ1-M-25/2

25

 

2

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ1-M-32/1.6

32

 

1.6

GDJ1-M-40/1.3

40

 

1.3

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ1-M-50/1.0

50

 

1.0

GDJ1-M-63/0.8

63

 

0.8

GDJ1-M-80/0.63

80

 

0.63

GDJ1-M-100/0.5

100

 

0.5

GB/T9119 DN15PN6RF

GB/T9119 DN15PN6RF

GDJ1-M-125/0.4

125

 

0.4

GDJ1-M-160/0.32

160

 

0.32

GDJ1-M-200/0.25

200

 

0.25


Install Dimensions

Model

A1

A2

B

C

D

GDJ1-M-2/5

169

169

126

Φ12 (outside diameter) *3 hose

Φ12 (outside diameter) *3 hose

GDJ1-M3.2/3.2

186

186

134

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ1-M-5/2.0

182

182

138

GDJ1-M-8/1.3

190

190

139

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ1-M-14/0.8

194

194

142

GDJ1-M-10/5

169

169

126

Φ12 (outside diameter) *3 hose

Φ12 (outside diameter) *3 hose

GDJ1-M-12.5/4

GDJ1-M-16/3.2

186

186

134

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ1-M-20/2.5

GDJ1-M-25/2

182

182

138

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ1-M-32/1.6

GDJ1-M-40/1.3

190

190

139

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ1-M-50/1.0

GDJ1-M-63/0.8

194

194

142

GDJ1-M-80/0.63

GDJ1-M-100/0.5

239

169

145

GB/T9119 DN15PN6RF

GB/T9119 DN15PN6RF

GDJ1-M-125/0.4

GDJ1-M-160/0.32

GDJ1-M-200/0.25


Installation Diagram

hydraulic diaphragm dosing pump installation diagram

GDJ2-M Hydraulic diaphragm dosing metering pump
Parameters

Type

 

 

Flow

L/h

Max Pressure MPa

inlet pipe connections(D)

outlet pipe connections(C)

Motor

0.37kW

Motor

0.55kW

Motor

0.75kW

GDJ2-M-5/16

5

16

 

 

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ2-M-9/10

9

10

 

 

GDJ2-M-15/6.3

15

6.3

 

 

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-18/16(6.3)

18

6.3

16

 

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ2-M-22/12.5(5)

22

5

 

125

GDJ2-M-25/4

25

4

 

 

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-32/10(4)

32

4

10

 

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ2-M-40/8(3.2)

40

3.2

 

8

GDJ2-M-40/2.5

40

2.5

 

 

DN15-PN6 RF GB/T9119

DN15-PN40 RF GB/T9119

GDJ2-M-50/6.3(2.5)

50

2.5

6.3

 

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-63/5(2)

63

2

 

5

GDJ2-M-80/4(1.6)

80

1.6

4

 

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-100/3.2(1.3)

100

1.3

 

3.2

GDJ2-M-125/2.5(1)

125

1

2.5

 

DN15-PN6 RF GB/T9119

DN15-PN40 RF GB/T9119

GDJ2-M-160/2(0.8)

160

0.8

 

2

GDJ2-M-200/1.6(0.63)

200

0.63

1.6

 

GDJ2-M-250/1.3

250

 

1.3

 

GDJ2-M-320/1

320

 

1

 

DN20-PN6 RF GB/T9119

DN20-PN40 RF GB/T9119

GDJ2-M-400/0.8

400

 

0.8

 

GDJ2-M-500/0.63

500

 

0.63

 

DN25-PN6 RF GB/T9119

DN25-PN6 RF GB/T9119

GDJ2-M-630/0.5

630

 

0.5

 

GDJ2-M-800/0.4

800

 

0.4

 

DN32-PN6 RF GB/T9119

DN32-PN6 RF GB/T9119

GDJ2-M-1000/0.32

1000

 

0.32

 

Install Dimensions

Type

A1

A2

B

C

D

GDJ2-M-5/16

204

204

147

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ2-M-9/10

198

198

147

GDJ2-M-15/6.3

202

202

148

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-18/16(6.3)

204

204

147

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ2-M-22/12.5(5)

GDJ2-M-25/4

202

202

148

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-32/10(4)

198

198

147

Φ14 (outside diameter) *3 hose

Φ14 (outside diameter) *3 hose

GDJ2-M-40/8(3.2)

GDJ2-M-40/2.5

245

175

156

DN15-PN40 RF GB/T9119

DN15-PN6 RF GB/T9119

GDJ2-M-50/6.3(2.5)

202

202

148

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-63/5(2)

GDJ2-M-80/4(1.6)

202

202

148

Φ18 (outside diameter) *3 hose

Φ18 (outside diameter) *3 hose

GDJ2-M-100/3.2(1.3)

GDJ2-M-125/2.5(1)

239

169

155

DN15-PN40 RF GB/T9119

DN15-PN6 RF GB/T9119

GDJ2-M-160/2(0.8)

GDJ2-M-200/1.6(0.63)

245

175

156

GDJ2-M-250/1.3

GDJ2-M-320/1

248

198

165

DN20-PN40 RF GB/T9119

DN20-PN6 RF GB/T9119

GDJ2-M-400/0.8

GDJ2-M-500/0.63

266

216

179

DN25-PN6 RF GB/T9119

DN25-PN6 RF GB/T9119

GDJ2-M-630/0.5

GDJ2-M-800/0.4

272

252

179

DN32-PN6 RF GB/T9119

DN32-PN6 RF GB/T9119

GDJ2-M-1000/0.32

Installation Diagram 

high-performance diaphragm pump installation diagram

GDJ3-M high pressure hydraulic diaphragm dosing pump
Parameters

Type

Flow

L/h

Max Pressure MPa

inlet pipe connections(D)

outlet pipe connections(C)

Motor

1.1kW

Motor

1.5kW

GDJ3-M-22/20(12.5)

22

12.5

20

Φ18(outside diameter)*4 hose

Φ18(outside diameter)*4 hose

GDJ3-M-28/20(10)

28

10

20

GDJ3-M-38/20(8)

38

8

20

Φ18(outside diameter)*3 hose

Φ18(outside diameter)*3 hose

GDJ3-M-48/16(12.5)

48

12.5

16

GDJ3-M-63/12.5(5)

63

5

12.5

GDJ3-M-80/10(4)

80

4

10

GDJ3-M-100/8(3.2)

100

3.2

8

DN15-PN5 RF GB/T9119

DN15-PN110 RF GB/T9116.1

GDJ3-M-125/6.3(2.5)

125

2.5

6.3

GDJ3-M-160/5(2)

160

2

5

DN15-PN5 RF GB/T9119

DN15-PN50 RF GB/T9116.1

GDJ3-M-200/4(1.6)

200

1.6

4

GDJ3-M-250/3.2(1.3)

250

1.3

3.2

DN20-PN6 RF GB/T9119

DN20-PN40 RF GB/T9119

GDJ3-M-320/2.5(1)

320

1

2.5

GDJ3-M-400/2(0.8)

400

0.8

2

DN20-PN6 RF GB/T9119

DN20-PN40 RF GB/T9119

GDJ3-M-500/1.6(0.63)

500

0.63

1.6

GDJ3-M-630/1.3(0.5)

630

0.5

1.3

DN25-PN6 RF GB/T9119

DN25-PN40 RF GB/T9119

GDJ3-M-800/1(0.4)

800

0.4

1

GDJ3-M-1000/0.8(0.32)

1000

0.32

0.8

DN32-PN6 RF GB/T9119

DN32-PN40 RF GB/T9119

GDJ3-M-1250/0.63(0.25)

1250

0.25

0.63

GDJ3-M-1600/0.5(0.2)

1600

0.2

0.5

DN40-PN6 RF GB/T9119

DN40-PN6 RF GB/T9119

GDJ3-M-2000/0.4

2000

 

0.4

Install Dimensions

Type

A1

A2

B

C

D

GDJ3-M-22/20(12.5)

210

210

180

Φ18(outside diameter)x4hose

Φ18(outside diameter)x4hose

GDJ3-M-28/20(10)

GDJ3-M-38/20(8)

210

210

180

Φ18(outside diameter)*3hose

Φ18(outside diameter)x3hose

GDJ3-M-48/16(12.5)

GDJ3-M-63/12.5(5)

GDJ3-M-80/10(4)

GDJ3-M-100/8(3.2)

246

206

188

DN15-PN110 RF GB/T9116.1

DN15-PN5 RF GB/T9119

GDJ3-M-125/6.3(2.5)

GDJ3-M-160/5(2)

222

212

188

DN15-PN50 RF GB/T9116.1

DN15-PN5 RF GB/T9119

GDJ3-M-200/4(1.6)

GDJ3-M-250/3.2(1.3)

218

218

189

DN20-PN40 RF GB/T9119

DN20-PN6 RF GB/T9119

GDJ3-M-320/2.5(1)

GDJ3-M-400/2(0.8)

241

201.5

192

DN20-PN40 RF GB/T9119

DN20-PN6 RF GB/T9119

GDJ3-M-500/1.6(0.63)

GDJ3-M-630/1.3(0.5)

249

229

195

DN25-PN40 RF GB/T9119

DN25-PN6 RF GB/T9119

GDJ3-M-800/1(0.4)

GDJ3-M-1000/0.8(0.32)

278

258

202

DN32-PN40 RF GB/T9119

DN32-PN6 RF GB/T9119

GDJ3-M-1250/0.63(0.25)

GDJ3-M-1600/0.5(0.2)

291

271

207

DN40-PN6 RF GB/T9119

DN40-PN6 RF GB/T9119

GDJ3-M-2000/0.4

Installation Diagram 

chemical diaphragm dosing pump installation diagram

GDJ4-M hydraulic diaphragm dosing pump

Parameters

Type

Flow

L/h

Max Pressure MPa

inlet pipe connections(D)

outlet pipe connections(C)

Motor

1.5kW

Motor

2.2kW

GDJ4-M-70/20(10)

70

10

20

Φ20(outside diameter)*4hose

Φ20(outside diameter)*4hose

GDJ4-M-90/16(8)

90

8

16

GDJ4-M-120/12.5(6.3)

120

6.3

12.5

DN15-PN6 RF GB/T9119

DN15-PN150 RF GB/T9116.1

GDJ4-M-150/10(5)

150

5

10

GDJ4-M-200/8(4)

200

4

8

DN15-PN6 RF GB/T9119

DN15-PN110 RF GB/T9116.1

GDJ4-M-250/6.3(3.2)

250

3.2

6.3

GDJ4-M-320/5(2.5)

320

2.5

5

DN20-PN6 RF GB/T9119

DN20-PN50 RF GB/T9116.1

GDJ4-M-400/4(2)

400

2

4

GDJ4-M-500/3.2(1.6)

500

1.6

3.2

DN25-PN6 RF GB/T9119

DN25-PN40 RF GB/T9119

GDJ4-M-630/2.5(1.25)

630

1.25

2.5

GDJ4-M-800/2(1)

800

1

2

DN32-PN6 RF GB/T9119

DN32-PN40 RF GB/T9119

GDJ4-M-1000/1.6(0.8)

1000

0.8

1.6

GDJ4-M-1250/1.25(0.63)

1250

0.63

1.25

DN40-PN6 RF GB/T9119

DN40-PN40 RF GB/T9119

GDJ4-M-1600/1(0.5)

1600

0.5

1

GDJ4-M-2000/0.8(0.4)

2000

0.4

0.8

DN50-PN6 RF GB/T9119

DN50-PN6 RF GB/T9119

GDJ4-M-2500/0.63(0.32)

2500

0.32

0.63

GDJ4-M-3200/0.5

3200

 

0.5

DN65-PN6 RF GB/T9119

DN65-PN6 RF GB/T9119

GDJ4-M-4000/0.4

4000

 

0.4

Install Dimensions

Type

A1

A2

B

C

D

GDJ4-M-70/20(10)

225

225

186

Φ20(outside diameter)*4hose

Φ20(outside diameter)*4hose

GDJ4-M-90/16(8)

GDJ4-M-120/12.5(6.3)

256

206

196

DN15-PN150 RF GB/T9116.1

DN15-PN6 RF GB/T9119

GDJ4-M-150/10(5)

GDJ4-M-200/8(4)

222

212

197

DN15-PN110 RF GB/T9116.1

DN15-PN6 RF GB/T9119

GDJ4-M-250/6.3(3.2)

GDJ4-M-320/5(2.5)

248

246

203

DN20-PN50 RF GB/T9116.1

DN20-PN6 RF GB/T9119

GDJ4-M-400/4(2)

GDJ4-M-500/3.2(1.6)

266

252

206

DN25-PN40 RF GB/T9119

DN25-PN6 RF GB/T9119

GDJ4-M-630/2.5(1.25)

GDJ4-M-800/2(1)

272

252

208

DN32-PN40 RF GB/T9119

DN32-PN6 RF GB/T9119

GDJ4-M-1000/1.6(0.8)

GDJ4-M-1250/1.25(0.63)

285

265

214

DN40-PN40 RF GB/T9119

DN40-PN6 RF GB/T9119

GDJ4-M-1600/1(0.5)

GDJ4-M-2000/0.8(0.4)

294

294

223

DN50-PN6 RF GB/T9119

DN50-PN6 RF GB/T9119

GDJ4-M-2500/0.63(0.32)

GDJ4-M-3200/0.5

321

321

238

DN65-PN6 RF GB/T9119

DN65-PN6 RF GB/T9119

GDJ4-M-4000/0.4

Installation Diagram 

large flow hydraulic diaphragm metering pump installation diagram

GDJ5-M hydraulic diaphragm metering pump

Parameters

Type

Flow

L/h

Max Pressure MPa

inlet pipe connections(D)

outlet pipe connections(C)

Motor

5.5kW

Motor

7.5kW

GDJ5-M-170/20(16)

170

16

20.0

DN15-PN6RF(Rp) GB/T9119

DN15-PN260 RF GB/T9116.1

GDJ5-M-220/20(12.5)

220

12.5

20.0

GDJ5-M-300/20(10)

300

10

20.0

DN20-PN6 RF(Rp) GB/T9119

DN20-PN260 RF GB/T9116.1

GDJ5-M-380/20(8)

380

8

20.0

GDJ5-M-500/16(6.3)

500

6.3

16.0

DN25-PN6 RF(Rp) GB/T9119

DN25-PN150 RF GB/T9116.1

GDJ5-M-630/12.5(5)

630

5

12.5

GDJ5-M-800/10(4)

800

4.0

10.0

DN32-PN6 RF(Rp) GB/T9119

DN32-PN110 RF(NPT) GB/T9114

GDJ5-M-1000/8(3.2)

1000

3.2

8.0

GDJ5-M-1250/6.3(2.5)

1250

2.5

6.3

DN40-PN6 RF(Rp) GB/T9119

DN40-PN50 RF(NPT) GB/T9116.1

GDJ5-M-1600/5(2)

1600

2.0

5.0

GDJ5-M-2000/4(1.6)

2000

1.6

4.0

DN40-PN6 RF(Rp) GB/T9119

DN40-PN40 RF(Rp) GB/T9119

GDJ5-M-2500/3.2(1.25)

2500

1.25

3.2

GDJ5-M-3200/2.5(1)

3200

1.0

2.5

DN50-PN6 RF(Rp) GB/T9119

DN50-PN40 RF(NPT) GB/T9119

GDJ5-M-4000/2(0.8)

4000

0.8

2.0

GDJ5-M-5000/1.6(0.63)

5000

0.63

1.6

DN65-PN6 RF(Rp) GB/T9119

DN65-PN40 RF(NPT) GB/T9119

GDJ5-M-6300/1.25(0.5)

6300

0.5

1.25

Install Dimensions

Type

A1

A2

B

C

D

GDJ5-M-170/20(16)

259

232

152

DN15-PN260 RF GB/T9116.1

DN15-PN6RF(Rp) GB/T9119

GDJ5-M-220/20(12.5)

GDJ5-M-300/20(10)

259

232

152

DN20-PN260 RF GB/T9116.1

DN20-PN6 RF(Rp) GB/T9119

GDJ5-M-380/20(8)

GDJ5-M-500/16(6.3)

323

203

174

DN25-PN150 RF GB/T9116.1

DN25-PN6 RF(Rp) GB/T9119

GDJ5-M-630/12.5(5)

GDJ5-M-800/10(4)

325

315

176

DN32-PN110 RF(NPT) GB/T9114

DN32-PN6 RF(Rp) GB/T9119

GDJ5-M-1000/8(3.2)

GDJ5-M-1250/6.3(2.5)

285

265

176

DN40-PN50 RF(NPT) GB/T9116.1

DN40-PN6 RF(Rp) GB/T9119

GDJ5-M-1600/5(2)

GDJ5-M-2000/4(1.6)

299

279

177

DN40-PN40 RF(Rp) GB/T9119

DN40-PN6 RF(Rp) GB/T9119

GDJ5-M-2500/3.2(1.25)

GDJ5-M-3200/2.5(1)

312

312

185

DN50-PN40 RF(NPT) GB/T9119

DN50-PN6 RF(Rp) GB/T9119

GDJ5-M-4000/2(0.8)

GDJ5-M-5000/1.6(0.63)

349

349

193

DN65-PN40 RF(NPT) GB/T9119

DN65-PN6 RF(Rp) GB/T9119

GDJ5-M-6300/1.25(0.5)

Installation Diagram 
industrial electric chemical metering pump installation diagram

GDJ6-M high pressure hydraulic diaphragm metering pump

Parameters

Type

Flow

L/h

Max Pressure MPa

inlet pipe connections(D)

outlet pipe connections(C)

Motor

11kW

Motor

18.5kW

GDJ6-M-620/20(16)

620

16

25

DN32-PN6RF(Rp) GB/T9119

DN32-PN260RF GB/T9116.1

GDJ6-M-780/20(12.5)

780

12.5

20

GDJ6-M-1000/16(10)

1000

10

16

DN32-PN6RF(RP) GB/T9119

DN32-PN150RF(NPT) GB/T9116.1

GDJ6-M-1250/12.5(8)

1250

8

12.5

GDJ6-M-1600/10(6.3)

1600

6.3

10

DN40-PN6RF(Rp) GB/T9119

DN40-PN110RF(NPT) GB/T9116.1

GDJ6-M-2000/8(5)

2000

5

8

GDJ6-M-2500/6.3(4)

2500

4

6.3

DN50-PN6RF(Rp) GB/T9119

DN50-PN50RF(NPT) GB/T9116.1

GDJ6-M-3200/5(3.2)

3200

3.2

5

GDJ6-M-4000/4(2.5)

4000

2.5

4

DN65-PN6RF(Rp) GB/T9119

DN65-PN40RF(Rp) GB/T9119

GDJ6-M-5000/3.2(2)

5000

2

3.2

GDJ6-M-6300/2.5(1.6)

6300

1.6

2.5

DN80-PN6RF(Rp) GB/T9119

DN80-PN40RF(Rp) GB/T9119

GDJ6-M-8000/2(1.25)

8000

1.25

2

GDJ6-M-10000/1.6(1)

10000

1

1.6

DN100-PN6RF(Rp) GB/T9119

DN100-PN40RF(Rp) GB/T9119

GDJ6-M-12500/1.25(0.8)

12500

0.8

1.25

GDJ6-M-16000/1.0(0.6)

16000

0.6

1.0

DN100-PN6RF(Rp) GB/T9119

DN100-PN40RF(Rp) GB/T9119

Install Dimensions

Type

A1

A2

B

C

D

GDJ6-M-620/20(16)

361

361

180

DN32-PN260RF GB/T9116.1

DN32-PN6RF(Rp) GB/T9119

GDJ6-M-780/20(12.5)

GDJ6-M-1000/16(10)

361

361

180

DN32-PN150RF(NPT) GB/T9116.1

DN32-PN6RF(RP) GB/T9119

GDJ6-M-1250/12.5(8)

GDJ6-M-1600/10(6.3)

311

311

180

DN40-PN110RF(NPT) GB/T9116.1

DN40-PN6RF(Rp) GB/T9119

GDJ6-M-2000/8(5)

GDJ6-M-2500/6.3(4)

330

310

189

DN50-PN50RF(NPT) GB/T9116.1

DN50-PN6RF(Rp) GB/T9119

GDJ6-M-3200/5(3.2)

GDJ6-M-4000/4(2.5)

389

329

210

DN65-PN40RF(Rp) GB/T9119

DN65-PN6RF(Rp) GB/T9119

GDJ6-M-5000/3.2(2)

GDJ6-M-6300/2.5(1.6)

391

391

242

DN80-PN40RF(Rp) GB/T9119

DN80-PN6RF(Rp) GB/T9119

GDJ6-M-8000/2(1.25)

GDJ6-M-10000/1.6(1)

431

436

252

DN100-PN40RF(Rp) GB/T9119

DN100-PN6RF(Rp) GB/T9119

GDJ6-M-12500/1.25(0.8)

GDJ6-M-16000/1.0(0.6)

436

436

252

DN100-PN40RF(Rp) GB/T9119

DN100-PN6RF(Rp) GB/T9119

Installation Diagram 

hydraulic diaphragm dosing pump installation diagram

GDJ7-M high pressure hydraulic dosing metering pump

Parameters

Type

Flow

L/h

Max Pressure MPa

inlet pipe connections(D)

outlet pipe connections(C)

Motor

18.5kW

Motor

30kW

GDJ7-M-1600/20(16)

1600

16

20

DN50-PN40 RF(Rp) GB/T9114

DN50-PN260 RF GB/T9115.1

GDJ7-M-2000/20(12.5)

2000

12.5

20

GDJ7-M-2500/16(10)

2500

10

16

DN65-PN40 RF(Rp) GB/T9114

DN65-PN150 RF GB/T9115.1

GDJ7-M-3200/12.5(8)

3200

8

12.5

GDJ7-M-4000/10(6.3)

4000

6.3

10

DN80-PN40 RF(Rp) GB/T9114

DN80-PN110 RF(NPT) GB/T9114

GDJ7-M-5000/8(5)

5000

5

8

GDJ7-M-6300/6.3(5)

6300

5

6.3

DN80-PN40 RF(Rp) GB/T9114

DN80-PN110 RF(NPT) GB/T9114

GDJ7-M-6300/6.3(4)

6300

4

6.3

GDJ7-M-8000/5(3.2)

8000

3.2

5

DN80-PN40 RF(Rp) GB/T9114

DN80-PN50 RF(NPT) GB/T9114

GDJ7-M-10000/4(2.5)

10000

2.5

4

GDJ7-M-12500/3.2(2)

12500

2

3.2

DN100-PN40 RF(Rp) GB/T9114

DN100-PN40 RF(Rp) GB/T9114

GDJ7-M-16000/2.5(1.6)

16000

1.6

2.5

GDJ7-M-20000/2(1.25)

20000

1.25

2

DN125-PN25 RF(Rp) GB/T9114

DN125-PN25 RF(Rp) GB/T9114

GDJ7-M-25000/1.6(1)

25000

1

1.6

GDJ7-M-32000/1.25(0.8)

32000

0.8

1.25

DN150-PN16 RF(Rp) GB/T9114

DN150-PN16 RF(Rp) GB/T9114

GDJ7-M-40000/1(0.63)

40000

0.63

1

Install Dimensions

Type

A1

A2

B

C

D

GDJ7-M-1600/20(16)

382

334

255

DN50-PN260 RF GB/T9115.1

DN50-PN40 RF(Rp) GB/T9114

GDJ7-M-2000/20(12.5)

GDJ7-M-2500/16(10)

436

389

259

DN65-PN150 RF GB/T9115.1

DN65-PN40 RF(Rp) GB/T9114

GDJ7-M-3200/12.5(8)

GDJ7-M-4000/10(6.3)

416

378

266

DN80-PN110 RF(NPT) GB/T9114

DN80-PN40RF(Rp) GB/T9114

GDJ7-M-5000/8(5)

GDJ7-M-6300/6.3(5)

399

358

266

DN80-PN110 RF(NPT) GB/T9114

DN80-PN40 RF(Rp) GB/T9114

GDJ7-M-6300/6.3(4)

GDJ7-M-8000/5(3.2)

414

385

271

DN80-PN50 RF(NPT) GB/T9114

DN80-PN40 RF(Rp) GB/T9114

GDJ7-M-10000/4(2.5)

GDJ7-M-12500/3.2(2)

472

472

297

DN100-PN40 RF(Rp) GB/T9114

DN100-PN40 RF(Rp) GB/T9114

GDJ7-M-16000/2.5(1.6)

GDJ7-M-20000/2(1.25)

543

543

319

DN125-PN25 RF(Rp) GB/T9114

DN125-PN25 RF(Rp) GB/T9114

GDJ7-M-25000/1.6(1)

GDJ7-M-32000/1.25(0.8)

615

615

342

DN150-PN16 RF(Rp) GB/T9114

DN150-PN16RF(Rp) GB/T9114

GDJ7-M-40000/1(0.63)

Installation Diagram 

hydraulic diaphragm metering pump installation diagram

2GDJ2-M hydraulic high-performance diaphragm pump

Parameters

Type

Flow L/h

Discharge pressure

MPa

Plunger diameter

mm

Coverage

mm

Repetition

rpm

Motor power

KW

2GDJ2-M-7/25

7

25

9

22

80

0.55

2GDJ2-M-12/16

12

16

12

22

80

0.55

2GDJ2-M-20/10

20

10

16

22

80

0.55

2GDJ2-M-36/6.4

36

6.4

21

22

80

0.55

2GDJ2-M-60/40

60

40

27

22

80

0.55

2GDJ2-M-120/2.5

120

2.5

38

22

80

0.55

2GDJ2-M-132/1.6

132

1.6

40

22

80

0.55

2GDJ2-M-230/1.2

230

1.2

53

22

80

0.55

2GDJ2-M-380/1.0

380

1.0

68

22

80

0.75

2GDJ2-M-490/0.5

490

0.5

76

22

80

0.75

Install Dimensions

Type

DN

D

K

d

H1

H2

L

2GDJ2-M-7/25

8

75

50

33

142

182

820

2GDJ2-M-12/16

8

75

50

33

142

182

820

2GDJ2-M-20/10

8

75

50

33

142

182

820

2GDJ2-M-36/6.4

8

75

50

33

142

182

820

2GDJ2-M-60/40

8

75

50

33

142

182

820

2GDJ2-M-120/2.5

8

75

50

33

142

182

820

2GDJ2-M-132/1.6

12

95

65

65

147

147

820

2GDJ2-M-230/1.2

15

95

65

65

147

147

840

2GDJ2-M-380/1.0

15

95

65

65

147

147

820

2GDJ2-M-490/0.5

15

95

65

65

147

147

820

Installation Diagram 

alloy hydraulic diaphragm chemical dosing pump installation diagram

2GDJ3-M large flow hydraulic diaphragm metering pump

Parameters

Type

Flow L/h

Discharge pressure

MPa

Plunger diameter

mm

Coverage

mm

Repetition

rpm

Motor power

KW

2GDJ3-M-22/64

22

64

10

50

90

2.2

2GDJ3-M-33/64

33

64

12

50

90

2.2

2GDJ3-M-32/50

32

50

12

50

90

2.2

2GDJ3-M-48/50

48

50

15

50

90

2.2

2GDJ3-M-56/40

56

40

16

50

90

2.2

2GDJ3-M-84/40

84

40

20

50

90

2.2

2GDJ3-M-96/32

96

32

21

50

90

2.2

2GDJ3-M-144/25

144

25

26

50

90

2.2

2GDJ3-M-150/25

150

25

27

50

90

2.2

2GDJ3-M-224/20

224

20

33

50

90

3

2GDJ3-M-244/16

244

16

34

50

90

3

2GDJ3-M-366/12.5

366

12.5

42

50

90

3

2GDJ3-M-400/10

400

10

43

50

90

3

2GDJ3-M-600/10

600

10

53

50

90

3

2GDJ3-M-636/6.4

636

6.4

55

50

90

3

2GDJ3-M-954/6.4

954

6.4

67

50

90

4

2GDJ3-M-1040/5.0

1040

5.0

70

50

90

4

2GDJ3-M-1560/4.0

1560

4.0

86

50

90

4

2GDJ3-M-1720/3.2

1720

3.2

90

50

90

4

2GDJ3-M-2560/2.5

2560

2.5

110

50

90

4

2GDJ3-M-2160/2.0

2160

2.0

101

50

90

4

2GDJ3-M-3240/1.6

3240

1.6

124

50

90

4

2GDJ3-M-2770/1.6

2770

1.6

114

50

90

4

2GDJ3-M-4150/1.0

4150

1.0

140

50

90

4

2GDJ3-M-6200/0.5

6200

0.5

171

50

90

4

Install Dimensions

Type

DN

D

K

d

H1

H2

L

2GDJ3-M-22/64

8

90

60

41

155

195

1100

2GDJ3-M-33/64

8

90

60

41

155

195

1100

2GDJ3-M-32/50

8

90

60

41

155

195

1100

2GDJ3-M-48/50

8

90

60

41

155

195

1100

2GDJ3-M-56/40

8

90

60

41

155

195

1100

2GDJ3-M-84/40

8

90

60

41

155

195

1100

2GDJ3-M-96/32

8

90

60

41

155

195

1100

2GDJ3-M-144/25

10

90

60

41

162

202

1100

2GDJ3-M-150/25

10

90

60

41

162

202

1100

2GDJ3-M-224/20

10

90

60

41

162

202

1100

2GDJ3-M-244/16

10

90

60

41

162

202

1100

2GDJ3-M-366/12.5

12

95

66

46

198

198

1120

2GDJ3-M-400/10

12

95

66

46

198

198

1120

2GDJ3-M-600/10

12

95

66

46

198

198

1120

2GDJ3-M-636/6.4

12

95

66

46

198

198

1120

2GDJ3-M-954/6.4

16

105

85

56

214

254

1120

2GDJ3-M-1040/5.0

16

105

85

56

214

254

1120

2GDJ3-M-1560/4.0

16

105

85

56

214

254

1120

2GDJ3-M-1720/3.2

16

105

85

56

214

254

1120

2GDJ3-M-2560/2.5

16

105

85

56

214

254

1120

2GDJ3-M-2160/2.0

26

115

85

65

205

245

1260

2GDJ3-M-3240/1.6

26

115

85

65

205

245

1260

2GDJ3-M-2770/1.6

26

115

85

65

205

245

1260

2GDJ3-M-4150/1.0

35

135

98

75

240

280

1350

2GDJ3-M-6200/0.5

35

135

98

75

240

280

1350

Installation Diagram 

high pressure metering pump plunger dosing pump installation diagram

2GDJ4-M industrial electric high pressure hydraulic diaphragm dosing metering pump

Parameters

Type

Flow L/h

Discharge pressure

MPa

Plunger diameter

mm

Coverage

mm

Repetition

rpm

Motor power

KW

2GDJ4-M-45/64

45

64

12

80

90

4

2GDJ4-M-67/64

67

64

14

80

90

4

2GDJ4-M-80/50

80

50

15

80

90

4

2GDJ4-M-120/50

120

50

19

80

90

4

2GDJ4-M-135/40

135

40

20

80

90

4

2GDJ4-M-200/40

200

40

24

80

90

4

2GDJ4-M-220/32

220

32

25

80

90

4

2GDJ4-M-330/32

330

32

31

80

90

4

2GDJ4-M-370/25

370

25

33

80

90

5.5

2GDJ4-M-555/25

555

25

40

80

90

5.5

2GDJ4-M-580/20

580

20

41

80

90

5.5

2GDJ4-M-870/20

870

20

51

80

90

5.5

2GDJ4-M-900/16

900

16

52

80

90

5.5

2GDJ4-M-1350/16

1350

16

63

80

90

5.5

2GDJ4-M-1600/10

1600

10

69

80

90

5.5

2GDJ4-M-2400/10

2400

10

84

80

90

5.5

2GDJ4-M-2160/8

2160

8

80

80

90

5.5

2GDJ4-M-3240/6.4

3240

6.4

98

80

90

5.5

2GDJ4-M-2940/4

2940

4

93

80

90

5.5

2GDJ4-M-4400/2.5

4400

2.5

114

80

90

5.5

2GDJ4-M-3700/1.6

3700

1.6

104

80

90

5.5

2GDJ4-M-5550/1

5550

1

128

80

90

5.5

2GDJ4-M-4500/1

4500

1

115

80

90

5.5

2GDJ4-M-6700/0.8

6700

0.8

141

80

90

5.5

2GDJ4-M-10000/0.5

10000

0.5

172

80

90

5.5

2GDJ4-M-15500/0.5

15500

0.5

214

80

90

5.5

Install Dimensions

Type

DN

D

K

d

H1

H2

L

2GDJ4-M-45/64

8

90

60

41

303

353

1340

2GDJ4-M-67/64

8

90

60

41

303

353

1340

2GDJ4-M-80/50

8

90

60

41

303

353

1340

2GDJ4-M-120/50

12

95

65

46

303

353

1440

2GDJ4-M-135/40

12

95

65

46

303

353

1440

2GDJ4-M-200/40

12

95

65

46

303

353

1440

2GDJ4-M-220/32

12

95

65

46

303

353

1440

2GDJ4-M-330/32

16

105

85

56

194

244

1450

2GDJ4-M-370/25

16

105

85

56

194

244

1450

2GDJ4-M-555/25

16

105

85

56

194

244

1450

2GDJ4-M-580/20

16

105

85

56

194

244

1450

2GDJ4-M-870/20

25

115

85

65

212

262

1450

2GDJ4-M-900/16

25

115

85

65

212

262

1450

2GDJ4-M-1350/16

25

115

85

65

212

262

1450

2GDJ4-M-1600/10

25

115

85

65

212

262

1450

2GDJ4-M-2400/10

25

115

85

65

212

262

1450

2GDJ4-M-2160/8

25

115

85

65

212

262

1450

2GDJ4-M-3240/6.4

35

135

98

75

242

292

1460

2GDJ4-M-2940/4

35

135

98

75

242

292

1460

2GDJ4-M-4400/2.5

35

135

98

75

242

292

1460

2GDJ4-M-3700/1.6

40

150

110

84

242

292

1480

2GDJ4-M-5550/1

40

150

110

84

242

292

1480

2GDJ4-M-4500/1

50

160

125

108

252

302

1530

2GDJ4-M-6700/0.8

50

160

125

108

252

302

1530

2GDJ4-M-10000/0.5

80

195

160

135

730

670

1530

2GDJ4-M-15500/0.5

80

195

160

135

730

670

1530

Installation Diagram 

metering dosing pump diaphragm for water treatment plant installation diagram

Inquiry >
Products you need :
Your name :
Your tel :
* Your mail :
Your company :
Your country :
* Inquiry :